Kemppi MSF 53 Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Kemppi MSF 53. Kemppi MSF 53 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Operating manual • English
Käyttöohje • Suomi
Bruksanvisning • Svenska
Bruksanvisning • Norsk
Brugsanvisning • Dansk
Gebrauchsanweisung • Deutsch
Gebruiksaanwijzing • Nederlands
Manuel d’utilisation • Français
Manual de instrucciones • Español
Instrukcja obsługi • Polski
Инструкции по эксплуатации • По-русски
EN
FI
SV
NO
DA
DE
NL
FR
ES
PL
RU
FastMig
MSF 53, 55, 57
Vista de pagina 0
1 2 3 4 5 6 ... 31 32

Indice de contenidos

Pagina 1 - MSF 53, 55, 57

Operating manual • EnglishKäyttöohje • SuomiBruksanvisning • SvenskaBruksanvisning • NorskBrugsanvisning • DanskGebrauchsanweisung • DeutschGebruiksaa

Pagina 2

EN1.2.3 DuraTorque™ 400, 4 wheel wire feed mechanismWire guide tubesSs, Al, Fe, Mc, Fcø 0.6 ... 1.6 mm ø 2.5/64 mm, W000762, silver, plasticø 2.5/3

Pagina 3 - OPERATING MANUAL

EN2. INSTALLATION2.1 ASSEMBLY OF MIG SYSTEMAssemble the units in order mentioned below and follow mounting and operation instructions which are deliv

Pagina 4

EN2.4 MOUNTING AND LOCKING OF WIRE SPOOLLOCKED OPEN• Releaselockingnailsofwirereelhubbyturninglockingknobaquarterround.• Mountthespo

Pagina 5 - 1. PREFACE

EN2.7 ADJUSTMENT OF TIGHTNESS OF REEL BRAKEBrake force is adjusted through hole in locking device of spool hub by screwing the control screw (A) with

Pagina 6 - MSF 55, MSF 57

EN2.10.1 Installing gas bottleEBDGAFCNOTE! Always fasten gas bottle properly in vertical position in a special holder on the wall or on a carriage.

Pagina 7

EN2.12 OPERATION OF COOLING UNIT, FASTCOOL 10Operation of cooling unit is controlled in such a way that pump is started when welding is started. Afte

Pagina 8

ENWhen the adjustment of SETUP parameters has been conrmed with long press on button (10b), the adjustable parameter is selected via potentiometer (1

Pagina 9 - 1.2.2 Connection of system

ENUse of remote control units (13)Remote control unit is connected to the device by pressing button 13. The wire feed speed and welding voltage settin

Pagina 10 - Wire feed rolls

ENMIG 4T: MIG welding with four-sequence procedure of welding gun start switch1. switch pressed: shielding gas ow starts2. switch released: welding

Pagina 11 - 2. INSTALLATION

ENor remotely via the remote control unit linked to the unit’s remote-control connector. If settings are chosen to be performed via the gun controller

Pagina 13 - 2.10 SHIELD GAS

ENMemory functions (15)Storage of settingsThe memory functions can be used to record useful welding values in the memory. There are ten dierent memor

Pagina 14 - 2.11 MAIN SWITCH I/O

ENFastMig™ synergic MIG-programs1-MIG 1-MIGProg Wire mmMaterial Gas mixture Prog Wire mmMaterial Gas mixtureFe-group SS-group201 0.8 SS-316 Ar+2%CO²10

Pagina 15 - 3. CONTROL PANELS OPERATIONS

EN3.3 SETUP FUNCTIONS 10The unit is equipped with a number of functions that can be selected. Parameters can be set via the SETUP function. The SET

Pagina 16

ENCable CompensationCAL -5.0 ... 9.0 V/100 A(1.0 V/100 A) Cable compensation (MIG) for voltage dropNOTE! In crater ll, the initial value of the we

Pagina 17 - Main switch, ON/OFF (1)

EN4. OPERATIONS OF REMOTE CONTROL UNITS IN MSF WIRE FEED UNITR20R63R61R63 R61MIGSetting for wire feed:1...25 m/minSetting for voltage:10 V...max.

Pagina 18

EN5. FASTMIG™ ERROR CODESThe existence of possible faults in the equipment is investigated in connection with each wire feed unit start-up. If a faul

Pagina 19 - Additional MIG functions (13)

ENErr 171: Conguration not found for the deviceThe equipment’s internal data transmission has been cut o. The optional features cannot be used. Turn

Pagina 20 - Memory functions (15)

ENtwice a yearIn case of problems contact your KEMPPI dealer.7. ORDERING NUMBERSMSF 536065300SF 51200 mm, LED 6085100SF 52200 mm, LED 6085200MSF 5560

Pagina 21

ENRemote control unitsR10 5 m 6185409R10 10 m 618540901R 20 5 m 6185419RMT 10 PMT MIG-gun 6185475MIG -gunsPMT 25 6252514PMT 27 3 m 6252713PMT 27 4.5 m

Pagina 22 - 3.3 SETUP FUNCTIONS 10

EN8. DISPOSAL OF THE MACHINEDonotdisposeofelectricalequipmentwithnormalwaste!In observance of European Directive 2002/96/EC on waste electric

Pagina 23 - Crater Fill End Level

ENOPERATING MANUALEnglishFastMig MSF 53, 55, 57 / © Kemppi Oy / 1515

Pagina 24 - MSF WIRE FEED UNIT

EN10. WARRANTY POLICYKemppi Oy provides a warranty for products manufactured and sold by the company if defects in materials or workmanship occur. Wa

Pagina 26 - Other error codes:

19065201515www.kemppi.comKEMPPI OYKempinkatu 1PL 13FIN-15801 LAHTIFINLANDTel +358 3 899 11Telefax +358 3 899 [email protected]

Pagina 27 - 7. ORDERING NUMBERS

ENCONTENTS1. PREFACE ... 31.1 General ...

Pagina 28 - Interconnecting cables

EN1. PREFACE1.1 GENERALCongratulations on your choice of the FastMig™ MSF series power source. Reliable and durable, Kemppi products are aordable to

Pagina 29 - 9. TECHNICAL DATA

EN1.2.1 OPERATION CONTROL AND CONNECTORS1.2.3.4.5.6.7.8.MSF 531. Operation panel2. Connection of remote control unit3. Connection of welding gun EURO

Pagina 30 - 10. WARRANTY POLICY

ENFunctions of SF 51 and SF 54 function panel1. 2.11.9.3. 4. 6.5. 7.13.12.8.10. 1. Main switch 2. Display of wire feed speed/welding current 3.

Pagina 31

ENFunctions of SF 52 and SF 53 function panel1. 2.11.9.3.10.4. 6.5. 7.13.12.8.14.15 16. 17. 1. Main switch 2. a) Wire feed speed/welding current/s

Pagina 32

EN1.2.2 Connection of system7FastMig MSF 53, 55, 57 / © Kemppi Oy / 1515